wego

Detachable Coil and Delivery System for Intracranial Aneurysm Embolization

Densely-stuffed in, perfect seal off

Detachable Coil and Delivery System for Intracranial Aneurysm Embolization

Visee Coil

STABLE BASKET-STRUCTURE, DENSELY FILLED TO ANEURISM INSIDE-WALL

Stable hexahedral structure with 1 to 2 coil rings on each surface; forming a 90 degree to other surface with variable angle, which varies as different shapes of the arterial aneurysm.

DENSELY-STUFFED IN, PERFECT SEAL OFF

The minimum size 1.5mmx1mm; 2 options of standard and soft type, excellent for densely-stuffing and perfectly finishing.

RELIABLE DETACHING POWER BOX & STRONG ANTI-UNWINDING PERFORMANCE

RELIABLE DETACHING POWER BOX

Accurate and consistent detaching point, ensures faster detaching time and high stable detaching result.

Each Power Box equips with two 9V batteries, double-clicks confirmation on detaching alarming ensures zero false alarm.

STRONGER ANTI-UNWINDING PERFORMANCE

Using of unique smooth-tipping technique, each coil has special build-in anti-unwinding wire in medical grade, anti-unwinding force is above 0.5~0.8N.

HIGH COST-EFFECTIVE EMBOLIZATION OPERATION

Pre-operation
Intra-operation
Post-operation

CLINICAL EFFICACY CASE 1

PCOA (posterior communicating artery aneurysms) with daughter tumor, 5.1*6.2*5.9mm. Use 7 coils, one aneurysm with dense embolization.

Pre-operation
Intra-operation
Post-operation

CLINICAL EFFICACY CASE 2

ACOA (anterior communicating artery aneurysms), boot shape, 2.1*2.6*4.4mm; Use 5 coils, one aneurysm with dense embolization.

PRECISE TECHNOLOGY

  • Applicable to mathron microcatheters
  • Finer wire diameter
  • Larger loop diameter
  • Ensure the flexibility of coils and sealing compactness
  • Joints by micro welding technique
  • Biological adhesive technique
  • Reduce the oscillation of the microcatheter tip in the process of delivery
  • Ensure the stability of detachment and flexibility of delivery system
  • Unique wire diameter and winding coefficient
  • Unique setting parameters for time and temperature control
  • Unique traceable code for device identification

Product Ordering Information

Specification Diameter(mm) Length(cm)
SEDC10-1.5-01 1.5 1
SEDC10-1.5-02 1.5 2
SEDC10-02-01 2 1
SEDC10-02-02 2 2
SEDC10-02-03 2 3
SEDC10-02-04 2 4
SEDC10-02-06 2 6
SEDC10-2.5-06 2.5 6
SEDC10-2.5-08 2.5 8
SEDC10-03-03 3 3
SEDC10-03-04 3 4
SEDC10-03-06* 3 6
SEDC10-03-08* 3 8
SEDC10-03-10 3 10
SEDC10-03-12 3 12
SEDC10-3.5-06 3.5 6
SEDC10-3.5-08 3.5 8
SEDC10-04-04 4 4
SEDC10-04-06 4 6
SEDC10-04-08* 4 8
SEDC10-04-10* 4 10
SEDC10-04-12 4 12
SEDC10-04-15 4 15
SEDC10-05-10* 5 10
SEDC10-05-12* 5 12
SEDC10-05-15* 5 15
SEDC10-06-12* 6 12
SEDC10-06-15* 6 15
SEDC10-06-20* 6 20
Specification Diameter(mm) Length(cm)
SEDC14-06-20 6 20
SEDC14-06-25 6 25
SEDC14-07-20 7 20
SEDC14-07-30* 7 30
SEDC14-08-30* 8 30
SEDC14-09-30* 9 30
SEDC14-10-30* 10 30
SEDC14-12-30 12 30
SEDC14-12-40 12 40
SEDC14-12-50 12 50
SEDC14-14-30 14 30
SEDC14-14-40 14 40
SEDC14-14-50 14 50
SEDC14-16-30 16 30
SEDC14-16-40 16 40
SEDC14-16-50 16 50
SEDC14-18-30 18 30
SEDC14-18-40 18 40
SEDC14-18-50 18 50
SEDC14-20-30 20 30
SEDC14-20-40 20 40
SEDC14-20-50 20 50
APPLICABLE TO DIAMETER OF MICRO-CATHETER;0.015”-0.017”
*Available in several specification, contact manufacturer for further details